Test Reports

Glassfibre Reinforced Concrete (GFRC) Performance Requirements in accordance with BS 6432: 1984

Product Properties (GFRC) Product Performance Requirement Product Performance by Far Eastern GRC Reference to test report
Characteristics Limit of Proportionality (LOP)
>5.0N/mm2
11.82N/mm2 (average mean results)
TÜV SÜD Test report GRC-BS EN 1170-5 Measuring bending strength 11 May 2018
Characteristic Modulus of Rupture (MOR)
>8.0N/mm2
27.43 N/mm2 (average mean results)
TÜV SÜD Test report 11 May 2018 as above
Dry Bulk Density
>1,800kg/m3
2140 kg/m3
TÜV SÜD Test GRC BS EN 1170-6 Absorption of water by immersion and determination of dry density 9 May 2018

Please contact our office for a copy of the test reports